The WriteRiverWare command writes one time series to the specified RiverWare format file. See the RiverWare Input Type Appendix for more information about the file format.

Command Editor

The following dialog is used to edit the command and illustrates the syntax of the command.

WriteRiverWare

WriteRiverWare Command Editor (see also the full-size image)

Command Syntax

The command syntax is as follows:

WriteRiverWare(Parameter="Value",...)

Command Parameters

Parameter                        Description Default                           
TSList
required
Indicates the list of time series to be processed, one of:
  • AllMatchingTSID – all time series that match the TSID (single TSID or TSID with wildcards) will be processed.
  • AllTS – all time series before the command.
  • SelectedTS – the time series are those selected with the SelectTimeSeries command.
AllTS
TSID The time series identifier or alias for the time series to be processed, using the * wildcard character to match multiple time series. Can be specified using ${Property}. Required if TSList=*TSID
OutputFile
required
The RiverWare file to write. The path to the file can be absolute or relative to the working directory. The Browse button can be used to select the file to write (if a relative path is desired, delete the leading path after the select). Can be specified with ${Property} notation. None – must be specified.
WriteHeaderComments Indicate whether # Comments should be written at the top of the file: True or False True
Units The data units to be output. Specify units that are recognized by RiverWare – the units are not actually converted but the new units string is used in the output file. Use the units in the time series.
Scale See the RiverWare Input Type Appendix. Time series values are divided by this value on output. 1
Set_units See the RiverWare Input Type Appendix. If specified, the value is output as provided with no modification to data values. Set_units is not output.
Set_scale See the RiverWare Input Type Appendix. If specified, the value is output as provided. Set_scale is not output.
Precision The number of digits after the decimal to write. 4

Examples

See the automated tests.

A sample command file to process a time series from the State of Colorado’s HydroBase database is as follows:

# 08213500 - RIO GRANDE RIVER AT THIRTY MILE BRIDGE NEAR CREEDE
08213500.DWR.Streamflow.Month~HydroBase
WriteRiverWare(TSList=AllTS,OutputFile="08213500.Month.RiverWare",Precision=2)

Troubleshooting