The Delta
command creates a new time series from an input time series.
The resulting values are computed as the difference (delta) between each value and the previous value.
Examples of use include:
- Disaggregating a cumulative time series into increments.
- Performing data quality control by detecting unexpected values.
The output value in the simplest case with default command parameters is
the current value minus the previous value.
The result is set to missing if this value cannot be computed due to missing input values,
and can also be set to missing if certain conditions met by optional data checks
(see the DeltaLimitAction
and IntervalLimitAction
parameters).
Irregular-interval time series that result in differences not being computed will have
missing values inserted in output at appropriate locations to maintain a consistent
timeline with the original data.
If appropriate, use fill commands to fill the data prior to or after calling the Delta
command.
The Delta
command will create as many output time series as there are input time series.
Alternatively, the CheckTimeSeries
command can be used to check time series
for changes that exceed a threshold; however,
the Delta
command handles the complexity of time series
that reset to a new starting value.
The output from Delta
can be used with the
CheckTimeSeries
command to check for changes above a criteria.
Simple Delta
A simple delta is calculated as:
-
If the current and previous values are not missing:
delta = value_current - value_previous
-
If either of the current or previous values are missing, the output time series missing is set to the missing value of the output time series (e.g.,
NaN
):delta = missing
Consequently, if the previous value is larger than the previous, the delta will be a positive value.
The following is an example of a daily (regular interval) streamflow time series with spring runoff and an unusual September flood event.
# Example for illustrating a simple delta using a streamflow time series:
# - use a station with a large storm
SetInputPeriod(InputStart="2013-05-01",InputEnd="2013-10-31")
# ABBREV=CLAFTCCO, USGS site ID=06752000 - CACHE LA POUDRE AT CANYON MOUTH NEAR FORT COLLINS
usgs:06752000.DWR.Streamflow-Avg.Day~HydroBaseWeb
#
# Simple delta.
Delta(Alias="%L-delta")
Streamflow Time Series input for Simple Delta (see full-size image)
The corresponding simple delta output time series shown below includes positive and negative values, with the flood event controlling the y-axis scale.
Simple Delta (see full-size image)
Additional parameters such as DataLimit
and IntervalLimit
can be used to check for unexpected values
and set the output as missing,
but must be applied with care so as to not discard valid large delta values.
Cumulative Time Series with Reset
A simple delta can be computed for cumulative time series as discussed in the previous section. However, cumulative time series may periodically reset (typically to zero) and require special attention.
This command can be used to create increments from a cumulative time series. For example, an annual precipitation accumulation can be converted into the precipitation increments. The increments can then be aggregated into interval data such as daily, monthly, and annual totals, and can be further analyzed. Data quality issues in the cumulative time series can also be evaluated.
A cumulative time series may reset periodically, for example, due to one or more of the following cases:
- Sensor rollover:
- hardware-based rollover, for example, a precipitation sensor that counts bucket tips, with a counter range that rolls over (e.g., 0 to 2048 tips)
- analog values (e.g., counter) or engineering values (e.g., inches or mm) may be reported
- the maximum value may not be reached before rollover due to maintenance (see the next itme)
- Maintenance reset:
- a cumulative time series reset may be tied to a maintenance schedule where sensors are recalibrated and field stations are inspected, typically during a dry season
- the sensor value is typically reset to zero for cumulative data like precipitation
- additional information like data flag indicating maintenance may be available (but is not currently used by this command)
- Time rollover:
- reset each day, season, or year
- may occur automatically or as part of a data workflow, for example "water year" accumulations
The determination of whether a reset is due to reaching a rollover maximum or is due to another condition such as maintenance can be handled in software, but a number of special conditions and constraints apply, as discussed below.
Automatic Reset with Zero Datum
If the cumulative time series is allowed to increase without bound before reset,
the ResetType=Auto
parameter can be used to automatically detect resets.
By default, the reset is assumed to be relative to a zero datum value
(the ResetAutoDatum
parameter can be used to specify a different datum).
For example, annual rain or snow cumulative precipitation can be processed to determine incremental precipitation.
Because no upper bound is set, it is not possible to add a delta above value before the reset,
as can be done with ResetType=Rollover
.
Therefore, the value after the reset is the value.
The following example is for flood warning system cumulative precipitation data.
Precipitation Time Series input for Variable Reset (see full-size image)
Computing a delta using ResetType=Auto
, ExpectedTrend=Increasing
,
and default AutoResetDatum
value of 0
shows the following output.
# Examples for documentation.
SetInputPeriod(InputStart="2020-01-01 00:00",InputEnd="CurrentToMinute")
#
# The following is a good example of rollover with maintenance.
6410.NovaStar5.PrecipAccum.IrregSecond~nsdataws-larimer
#
# Delta using defaults.
Delta(ExpectedTrend="Increasing",ResetType="Auto",Alias="%L-delta")
Precipitation Time Series input for Variable Reset (see full-size image)
The delta spike around 2021-01-25 is due to the cumulative precipitation values 1.46
, 1.42
, 1.46
,
which is interpreted as a reset to zero (delta value 1.42
) and then increase.
This error can be detected using DeltaLimit
because the bad delta value
in this case is larger than an expected delta (precipitation sensor bucket tip increment).
The CheckTimeSeries
command can also be
used on the original time series to check for small decreases that indicate problems.
Resets typically occur after a large accumulation.
The delta spike around 2022-03-22 indicates a possible problem with station transmitter,
where the sensor recorded increasing precipitation but the values were
only transmitted after several months.
Specifying the IntervalLimit
parameter can identify this issue
and ideally the original data can be corrected.
Automatic Reset with Variable Datum
If the cumulative time series is allowed to increase (or decrease) without bound before reset,
the ResetType=Auto
parameter can be used to automatically detect resets.
The following example from a flood warning system illustrates an example of this case.
The AutoResetDatum=Auto
parameter indicates that the reset datum is variable.
Currently this case (AutoResetDatum=Auto
) is not handled by the Delta
command.
If the datum for the 2021-02 reset is assumed to be the value after the reset,
then some delta value may be lost.
Using ResetType=Auto
and default zero datum value with DeltaLimit
will identify values
that don't reset to zero.
A simple delta may be OK if the values on either side of the reset are "flat",
which will result in no loss of delta values.
# Examples for documentation.
SetInputPeriod(InputStart="2020-01-01 00:00",InputEnd="CurrentToMinute")
#
# The following is an example of reset with inconsistent base value.
6130.NovaStar5.PrecipAccum.IrregSecond~nsdataws-larimer
Precipitation Time Series input for Variable Reset (see full-size image)
Rollover Reset with Bounding Values
This is appropriate, for example, where the cumulative value correspond to sensor counts such as precipitation sensor bucket tips.
If the cumulative time series is allowed to increase (or decrease) with reset using known bounding values, specify:
ExpectedTrend=Increasing
- to indicate an increasing accumulation (the following assumes increasing)RestType=Rollover
- to indicate that rollover is expectedResetMax
- maximum data value (rollover will useResetMax
- previous value as an "upper delta")ResetMin
- minimum data value (rollover will add this to the above "upper delta")RolloverDeltaLimit
:- if
ResetMax
minus the previous value is <=RolloverDeltaLimit
, a rollover will occur as described above - otherwise, a manual reset is assumed because values have not reached the
ResetMax
and the delta value is the difference between the value andResetMin
- if
RolloverFlag
- use to mark rollover resetsManualResetFlag
- use to mark manual resets
The normal case for rollover is that he input time series value will have a small value that follows a large value. The delta is computed as:
- The difference between
ResetMax
and the previous value. - Plus the difference between the value and
ResetMin
.
The normal case for a manual reset is that the delta after the reset is set to the value minus the datum.
The following example is for ResetMin=0
, ReetMax=20
, and RolloverDeltaLimit=.3
,
which cause both rollover and manual resets to occur.
Example Data Showing Rollover (R
flag) and Manual Reset (`r flag) (see full-size image)
Specific cases outside of normal data are:
- The previous value (before the reset) is >
ResetMax
. In this case the contribution from the out of range previous value is not added to the delta andFlag
value is assigned. A warning will be generated. - The current value (at reset) is out of range. A warning will be generated.
The above special cases result in somewhat arbitrary difference values because the inputs do not conform to expected values. Out of range values indicate erroneous data that should be corrected before being used in further analysis. Additional checks may be implemented in the future to detect and deal with bad data.
The DeltaLimit
and IntervalLimit
parameters can be used to identify potential data issues.
The IntervalLimit
parameter may not be appropriate if data collection stations are taken out of service
for some seasons.
Command Editor
The command is available in the following TSTool menu:
- Commands / Create Time Series
The following dialog is used to edit the command and illustrates the syntax of the command.
Delta
Command Editor for General Parameters (see full-size image)
Delta
Command Editor for Delta Limit Parameters (see full-size image)
Delta
Command Editor for Reset (Auto) Parameters (see full-size image)
Delta
Command Editor for Reset (Rollover) Parameters (see full-size image)
Delta
Command Editor for Output Table Parameters (see full-size image)
Delta
Command Editor for Output Properties Parameters (see full-size image)
Command Syntax
The command syntax is as follows:
Delta(Parameter="Value",...)
Command Parameters
Tab | Parameter | Description | Default |
---|---|---|---|
All | TSList |
Indicates the list of time series to be processed, one of:
|
AllTS |
TSID |
The time series identifier or alias for the time series to be processed, using the * wildcard character to match multiple time series. Can be specified using ${Property} . |
Required if TSList=*TSID |
|
EnsembleID |
The ensemble to be processed, if processing an ensemble. Can be specified using ${Property} . |
Required if TSList=*EnsembleID |
|
General | ExpectedTrend |
Indicates the expected trend of data for cumulative time series, used when values can reset:
|
Variable |
ResetType |
The reset type:
|
Unknown |
|
AnalysisStart |
The date/time to start analyzing data. Can be specified using ${Property} . |
Full period is analyzed. | |
AnalysisEnd |
The date/time to end analyzing data. Can be specified using ${Property} . |
Full period is analyzed. | |
Flag |
A string to flag problem values. Use a + in front of the flag to append. These flags can be overridden by more specific flag parameters.If specified as Auto , the following, default flags will be used with ResetType=Rollover :
Can be specified using ${Property} . |
Do not flag problem values. | |
Alias |
Alias to assign to created time series. A literal string can be specified or use %-specifiers to set the alias dynamically (e.g., %L-delta ) to use the location part of the identifier. |
None (but is highly recommended). | |
CopyDataFlags |
Whether to copy the data flags from the input time series to the delta time series (True ) or not (False ). Other flags can be specified with a leading + to append flags. |
False |
|
Delta Limit | DeltaLimit |
Use this and the following parameters to check for larger than expected delta values. The absolute value for the delta that is allowed. Larger delta values will result in a record in the output table (see the Output Table tab) and an action can be taken (see below). | |
DeltaLimit Action |
The action to be taken when a delta value is larger than DeltaLimit :
|
Keep |
|
DeltaLimit Flag |
The data flag to set when a delta value is larger than DeltaLimit . Use a + in front of the flag to append. Can be specified using ${Property} . |
No flag is set. | |
IntervalLimit |
Use this and the following parameters to check for larger than expected interval between previous and current values, only used with irregular interval time series. A larger than expected interval will result in a record in the output able (see the Output Table tab) and an action can be taken (see below). Can be specified using ${Property} . |
||
IntervalLimit Action |
The action to be taken when an interval value is larger than IntervalLimit :
|
Keep |
|
IntervalLimit Flag |
The data flag to set when an interval is larger than IntervalLimit . Use a + in front of the flag to append. Can be specified using ${Property} . |
Keep |
|
Reset - Auto For RestType= Auto |
AutoReset Datum |
When the data values reset, calculate the first delta value after the reset relative to the specified datum. Only used with ExpectedTrend=Increasing . Can be specified using ${Property} . |
0 (zero). |
AutoResetFlag |
Flag to set for automatic resets. Use a + in front of the flag to append. Can be specified with ${Property} . |
+A is used if Auto is specified. |
|
Reset - Rollover For ResetType= Rollover |
ResetMin |
The minimum expected data value, used when data are expected to roll over at ResetMax and reset to ResetMin , for example raw precipitation values that reset to zero when an accumulation sensor reaches its maximum value. |
Data bounds are not checked. Can be specified using ${Property} . |
ResetMax |
The maximum expected data value, used when data are expected to roll over at RestMax and reset to ResetMin , for example raw precipitation values that reset to zero when an accumulation sensor reaches its maximum value. |
Reset bounds are not checked. Can be specified using ${Property} . |
|
RolloverDelta Limit |
If specified:
|
Rollover is allowed for any delta reset. | |
RolloverFlag |
Flag to set for rollovers. Use a + in front of the flag to append. Can be specified with ${Property} . |
+R is used if Auto is specified. |
|
ManualReset Flag |
Flag to set for manual resets. Use a + in front of the flag to append. Can be specified with ${Property} . |
+r is used if Auto is specified. |
|
Reset Proximity Limit |
Future feature. The allowed delta that occurs prior to or after a reset, within the ResetProximityLimitInterval , used to check for bad data around a manual reset, such as calibration data. Can be specified using ${Property} . |
||
Reset Proximity LimitInterval |
Future feature. The interval used to check for ResetProximityLevel around a manual reset, such as calibration data that should not be included in data values. Can be specified using ${Property} . |
||
Reset Proximity LimitFlag |
Future feature. The flag to set when a ProximityLimit condition is met. Use a + in front of the flag to append. Can be specified using ${Property} . |
||
Output Table | TableID |
Identifier for output table to contain check results. Specify an existing table or new table to create. Can be specified using processor ${Property} . |
No table output. |
TableTSID Column |
Table column name for time series TSID. | Required for table. | |
TableTSID Format |
The specification to format the time series identifier to insert into the TSID column. Use the format choices and other characters to define a unique identifier. |
Required for table. | |
TableDateTime Column |
Table column name for date/time. | Column is not output. | |
TableValue Previous Column |
Table column name for time series data values for date/time previous to the current value matching DateTimeColumn . |
ValuePrevious |
|
TableValue Column |
Table column name for time series data values matching DateTimeColumn . |
Value |
|
TableDelta Calculated Column |
Table column name for delta after initial calculation. | DeltaCalculated |
|
TableAction Column |
Table column name for action taken due to checks. | Action |
|
TableDelta Column |
Table column name for delta after actions are taken (e.g., if set to missing). | Delta |
|
TableFlag Column |
Table column name for the flag corresponding to the action. | Flag |
|
TableProblem Column |
Table column name for data check problem messages. | Problem |
|
ProblemCount Property |
Name of processor property to set with count of problems (table length). Can use processor ${Property} and time series % or ${ts:Property} . |
No property is set. | |
ProblemCount TimeSeries Property |
Name of time series property to set with count of problems (table length). Can use processor ${Property} and time series % or ${ts:Property} . |
No property is set. |
Examples
See the automated tests.
See also the Overview section, which provides examples to explain the command functionality.
Example for ResetType=Auto
The following example illustrates using ResetType=Auto
and ExpectedTrend=Increasing
,
in this case for cumulative precipitation that resets at minute 53 of each hour.
Delta
Graph for ResetType=Auto
(see full-size image)
Delta
Table for ResetType=Auto
(see full-size image)
Troubleshooting
See the main TSTool Troubleshooting documentation.
See Also
CheckTimeSeries
commandSelectTimeSeries
command