Skip to content

Delay Table File - Daily (*.dld)

The daily delay table file contains coefficients to lag return flows. If the variable interv of the control file is a positive value, then interv values are expected for every pattern and data is expects to be provided as a percent. If the variable interv of the control file is a -1, then the number of values are specified for each pattern and data is expected to be provided as a percent. If the variable interv of the control file is a -100, then the number of values are specified for each pattern and data is expected to be provided as a decimal. This file is read by subroutine MDAINP.

Row-data Variable Description
Control Data
1 Format (a8, i4, (12f8.2))
1-1 idly Delay table ID
1-2 ndly(1) Number of entries in delay table idly
Include only if variable interv of the control file is equal to -1 or -100
1-3 dlyratd(j,1) Delay factor for time period j
Include as a percent if variable interv of the control file is positive or equal to -1
Include as a decimal if variable interv of the control file is equal to –100

Include ndly or interv delay entries

Repeat for the number of delay tables used in the diversion station file