Overview

The NWS Card format is an older format that will likely be phased out in the future.

The ReadNwsCard command reads all the time series in a National Weather Service River Forecast System CARD file (see the NWSCard Input Type Appendix). This command can be used to read the following formats:

  • Single time series format.
  • Ensemble format file, such as generated by the National Weather Service ESPADP software. Each trace will be identified using the historical year for the start of the trace (as the TSID sequence number), and will be available as a time series for other commands.

The full time series identifier for each time series is set using location = station identifier, data source = blank, data type = data type, and data interval = data interval from file header (see also the Read24HourAsDay parameter below).

Command Editor

The following dialog is used to edit the command and illustrates the syntax for the command when reading a single time series.

ReadNwsCard_SingleAlias

ReadNwsCard Command Editor for Reading a Single Time Series (see also the full-size image)

The following dialog illustrates reading an ensemble file, assigning the alias to Location-DataType-Interval-TraceNumber.

ReadNwsCard

ReadNwsCard Command Editor for Reading an Ensemble (see also the full-size image)

Command Syntax

The command syntax is as follows:

ReadNwsCard(Parameter="Value",...)

The following older command syntax is updated to the above syntax when a command file is read:

TS Alias = ReadNwsCard(Parameter=Value,...)

Command Parameters

Parameter                          Description Default                           
InputFile The name of the NWS Card input file to read, surrounded by double quotes to protect spaces and other special characters. None – must be specified.
Alias The alias to assign to the time series, as a literal string or using the special formatting characters listed by the command editor. The alias is a short identifier used by other commands to locate time series for processing, as an alternative to the time series identifier (TSID). None – must be specified.
EnsembleID Specify when reading an ensemble file to cause an ensemble object to be created, which can be referenced by other commands. Do not create an ensemble object.
EnsembleName The ensemble name corresponding to EnsembleID. None.
NewUnits The units to convert to after the read. Do not convert the units.
Read24HourAsDay If True, read 24Hour time series as if the data were Day interval. Because NWS Card format uses hours 1 to 24, treating as 24Hour results in values being saved at hour zero of the next day. Reading as Day interval causes the values to be stored without the shift. False – read as hourly and shift data at hour 24 to zero of the next day.
InputStart Not used with ensembles. The start of the period to read – specify if the read period should be different from the global query period. If Read24HourAsDay=True, specify the period using either hour 24 of the start day, or hour 0 of the next day. This parameter must be specified to hour precision with hour’s aligning with the file’s data. Use the global input period or if not specified read all the data in the file.
InputEnd Not used with ensembles. The end of the period to read – specify if the read period should be different from the global query period. If Read24HourAsDay=True, specify the period using either hour 24 of the start day, or hour 0 of the next day. This parameter must be specified to hour precision Use the global input period or if not specified read all the data in the file.

Examples

See the automated tests.

The following command file reads a card file containing one time series, reading 24Hour data as Day:

ReadNwsCard(Alias=”03567500”,InputFile="Data\03567500.CARD",InputStart="1960-01-01 24",InputEnd="2005-12-31 24",Read24HourAsDay=True)

The following example command reads an ensemble file, converts the data (from CFS) to CMS, and reads 24Hour data as Day:

ReadNwsCard(InputFile="Data/TDAO3.QA.ESP",EnsembleID="Ensemble_TDAO3",NewUnits="CMS",Read24HourAsDay=True)

Troubleshooting

See Also